EasyManua.ls Logo

Lucent Technologies FT-2000 OC-48 - Example 37 - PERFORMANCE-Retrieve-PM Threshold-Optics

Lucent Technologies FT-2000 OC-48
1578 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Craft Interface Terminal Usage
Issue 8.0 July 2002
11-117
Example 37 - PERFORMANCE-Retrieve-PM Threshold-Optics 11
Releases 7 and Later (Use the PERFORMANCE category.)
Address - Shows the specific optical line.
Bin - Shows the quarter-hour (QH) and day bins.
TX-Pwr - Shows if the automatic reporting of TCAs is enabled or
disabled for laser transmitted power.
Rcv-Pwr - Shows if the automatic reporting of TCAs is enabled or
disabled for laser received power.
LBC - Shows if the automatic reporting of TCAs is enable or
disabled for laser bias current.
Delta-1 91-07-15 23:15:15 EST
M Retrieve-PM Threshold-Optics:OC48:All: COMPLD
/* OC-48 Optics TCA Autonomous Reporting Status Report
=====================================================================
TCA Report TCA Report TCA Report
Address Bin TX-Pwr Rcv-Pwr LBC
=====================================================================
line-1e QH Enable Enable Enable
Day Disable Disable Disable
line-1w QH Enable Enable Enable
Day Disable Disable Disable
*/

Table of Contents