Craft Interface Terminal Usage
11-98 Issue 8.0 July 2002
Example 29 - PERFORMANCE-Retrieve-PM-Optics 11
Releases 3 and Later (Use the PERFORMANCE category.)
The above report shows the current performance-monitoring data for the OC-48
transmitter and receiver optics for all lines at an FT-2000 terminal. This report is
not available at the repeater site.
Address - Shows the address of the transmitter or receiver in the
FT-2000 terminal.
Start Time - Shows the time in hours and minutes for today only, or the
month and day are shown.
Transmit
Power
- Shows if the transmit power is within the specifications.
Receive
Power
- Shows if the receive power is within the specifications. A
hyphen (-) indicates that the quarter-hour bin data is
unavailable for the TRMTR circuit pack.
Laser bias
Current
- Shows if the laser bias current is within the specifications.
Delta-1 93-01-15 09:15:15 EST
M Retrieve-Performance Monitoring-Optics-OC48-All: COMPLD
/* OC48 Optics Performance Monitoring Status Report
Bin Start Time: quarter hour registers at yy-mm-dd hh:mm:ss
day registers at yy-mm-dd hh:mm:ss
=====================================================================
Address Start Transmit Receive Laser Bias
Time Power Power Current
=====================================================================
line-1e Today in range in range 1.04 in range
------------------------------------------------------------
09:15 in range in range 1.03 in range
=====================================================================
line-1w Today in range in range 0.97 in range
------------------------------------------------------------
09:15 in range in range 0.99 in range
*/
;
Information below is for Releases 3.0, 4.0, and 4.1
/* Optics Performance Monitoring Status Report
Last initialized: quarter hour registers at 93-01-15 09:15:00
day registers at 93-01-15 00:00:00
=====================================================================
Address Start Transmit Receive Laser Bias
Time Power Power Current
=====================================================================

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lucent Technologies FT-2000 OC-48 and is the answer not in the manual?

Lucent Technologies FT-2000 OC-48 Specifications

General IconGeneral
BrandLucent Technologies
ModelFT-2000 OC-48
CategoryNetwork Hardware
LanguageEnglish