Craft Interface Terminal Usage
11-68 Issue 8.0 July 2002
Example 16 - FAULT-Retrieve-History 11
The above report, normally a multiple page report, shows up to 500 of the most
recent events that have occurred in the FT-2000 System. The events are shown
with the most recent events at the top and include:
The beginning and end of FT-2000 System alarm and status conditions
Completed CIT inputs, except for Retrieve-modifier(s),
Operate-Alarm-Cutoff, and Test-LED inputs
Automatic provisioning state transitions
Operations systems interface
All login and logout attempts.
The fields of the report are described below:
Date of Event - Shows the month, day, hours, minutes, and seconds the
event occurred.
System Alarm - Shows the active alarm level at the time and date shown.
Possible alarms are CR, MJ, MN, ABN, NE ACTY, and dash
(-) when no alarms exist in the system.
Source Address - Shows the address of where the event occurred.
Event
Description
- A brief description of the event.
Lucent Technologies-FT-2000 96-07-19 23:15:15 EST
M Retrieve-History: COMPLD
/* Maintenance History Report
==========================================================================
Date Time System Source Event
of Event Alarm Address Description
==========================================================================
01-31 21:18:47 - cit-dce Set-Date
01-31 21:17:47 - cit-dce Login
01-31 21:16:17 - system Reset in progress - cleared
01-31 21:14:07 MJ system Reset in progress
01-31 21:12:23 MN Site-1-02 repeater bay env. input-cleared
....
....
01-30 19:49:32 MN Site-1-02 repeater bay environment input
*/
;