EasyManuals Logo

Lucent Technologies FT-2000 OC-48 User Manual

Lucent Technologies FT-2000 OC-48
1578 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #643 background imageLoading...
Page #643 background image
Maintenance Description
Issue 8.0 July 2002
9-91
Performance-Monitoring Parameter Thresholds 9
The current quarter-hour and current day thresholds for each
performance-monitoring parameter are provisionable using the CIT. Whenever the
current quarter-hour or the current day threshold for a given
performance-monitoring parameter is reached or exceeded, the FT-2000 OC-48
Add/Drop-Rings Terminal generates a threshold crossing alert (TCA). The TCA is
then entered into the appropriate performance-monitoring report. For more
information about provisioning thresholds using the CIT, refer to the
PERFORMANCE-Set-PM Threshold-Optics, PERFORMANCE-Set-PM
Threshold-Section, PERFORMANCE-Set-PM Threshold-Line,
PERFORMANCE-Set-PM Threshold-STS1, PERFORMANCE-Set-PM
Threshold-EC1, and PERFORMANCE-Set-PM Threshold-T3 inputs in the
"Local Provisioning" part of Volume I, Section 8, "Administration and
Provisioning." Also refer to the PERFORMANCE-Retrieve-PM
Threshold-Optics, PERFORMANCE-Retrieve-PM Threshold-Section,
PERFORMANCE-Retrieve-PM Threshold-Line,
PERFORMANCE-Retrieve-PM Threshold-STS1,
PERFORMANCE-Retrieve-PM Threshold-EC1,and
PERFORMANCE-Retrieve-PM Threshold-T3 inputs in Volume I, Section 11,
"Craft Interface Terminal Usage."
Threshold Crossing Alert Transmission to an OS9
Threshold crossing alerts are also reported to an OS via the X.25 interface using
TL1 messages.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lucent Technologies FT-2000 OC-48 and is the answer not in the manual?

Lucent Technologies FT-2000 OC-48 Specifications

General IconGeneral
BrandLucent Technologies
ModelFT-2000 OC-48
CategoryNetwork Hardware
LanguageEnglish