Circuit Pack Descriptions
7-88 Issue 8.0 July 2002
reset and the FAULT LED on the circuit pack is continuously lighted. If an
incoming OC-48 signal fails, the FAULT LED will flash on and off.
General Description of Operation 7
The OC48 RCVR A/D circuit pack accepts the incoming OC-48 signal (2.5 Gb/s)
and converts it to an electrical STS-48 signal. The STS-48 signal is descrambled
and demultiplexed into sixteen 155.52 Mb/s signals. The SONET transport
overhead bytes are also extracted and sent to the Overhead Controller - Terminal
[OHCTL (TERM)] circuit pack. The 839B2 and 839B4B OC48 RCVR A/D circuit
pack then passes the sixteen 155.52 Mb/s signals to the low speed interface
circuit packs or the OC48 TRMTR A/D circuit pack in the opposite direction
(bidirectional ring applications).
The 839B5 OC48 RCVR A/D circuit pack demultiplexes the STS-48 electrical
signal into sixteen 155.52 Mb/s signals, which are fanned out to 54 STS-3 output
ports through two parallel STS-1 time slot assignment (TSA) crosspoint switch
devices. The sixteen 155.52 Mb/s signals are then passed to the low speed
interface circuit packs or the OC48 TRMTR A/D circuit pack in the opposite
direction (bidirectional ring applications).
Detailed Description of Operation 7
Transmission Circuitry 7
Figure 7-27 shows an overall block diagram of 839B2 and 839B4B OC48 RCVR
A/D circuit packs, and Figure 7-28 shows an overall block diagram of the 839B5
and 839E5 OC48 RCVR A/D circuit pack. The OC48 RCVR A/D circuit pack
accepts one 2.5 Gb/s non-return-to-zero (NRZ) SONET compatible optical signal.
Fiber access to the OC48 RCVR A/D circuit pack is via a fixed
ST
-type buildout
block and a removable
ST
-type, FC/PC-type, or SC-type lightguide buildout on the
circuit pack faceplate. Lightguide buildouts are chosen based on the attenuation
desired, and the type of connector interface the single-mode lightguide jumper is
equipped with. There are three types of lightguide buildouts available for the
OC48 RCVR A/D circuit pack:
ST
-type, FC/PC-type, and SC-type. All
factory-equipped OC48 RCVR A/D circuit packs come with a removable
ST
-type
0-dB lightguide buildout. When installing or removing lightguide buildouts, do not
pull the beam (front tab) outward. Pulling the beam (front tab) outward could result
in breaking the beam (front tab).

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lucent Technologies FT-2000 OC-48 and is the answer not in the manual?

Lucent Technologies FT-2000 OC-48 Specifications

General IconGeneral
BrandLucent Technologies
ModelFT-2000 OC-48
CategoryNetwork Hardware
LanguageEnglish