Craft Interface Terminal Usage
Issue 8.0 July 2002
11-137
Example 47 - FAULT-Retrieve-State 11
Releases 4.1 and Later
The State Report shows a normal state at an FT-2000 Add/Drop-Rings Terminal,
meaning that there are no active protection switches, inhibits, lockouts, or other
abnormal conditions.
Delta-1 93-01-19 23:15:15 EST
M Retrieve-State:All: COMPLD
/* State Report
================================================================================
Address Circuit Port State Switch -Switch Priority-
Pack DSX OC48 State Active Deferred
================================================================================
DS1-in-pri i active -
DS1-in-sec i standby -
---------------------------------------------------------------------------
tg-1 TG3 active -
tg-2 TG3 active -
---------------------------------------------------------------------------
trmtr-1e TRMTR active - -
trmtr-1w TRMTR active - -
---------------------------------------------------------------------------
rcvr-1e RCVR active - -
rcvr-1w RCVR active - -
---------------------------------------------------------------------------
Continue report page-by-page?(y/n)Yes