Craft Interface Terminal Usage
11-66 Issue 8.0 July 2002
Example 15 - SECURITY-Retrieve-Far End Communications 11
Releases 3 and Later (Use the SECURITY category.)
The above report shows that access to a remote location over the data
communications channel (DCC) is enabled (access is allowed). The fields of the
report are described below:
Remote
Activity
Reporting
- Shows that remote reporting is enabled or disabled. For
example, when enabled, far-end activity is indicated by the
FE ACTY LED being lit and reported in the Retrieve-Network
Alarms Report.
Remote
Office
Alarms
- Shows that the remote office alarms are allowed to be
displayed locally (enabled) or not (disabled). For example,
when disabled, only local office alarms are reported locally.
Far End
Terminal
- For Release 3 only. Shows the far-end terminal
manufacturer, "Lucent Technologies" or "Other.
Lucent Technologies-FT-2000 96-07-19 23:15:15 EST
M Retrieve-Far End Communications: COMPLD
/* Far End Communication Configuration Report
=============================================================
Parameter Value
=============================================================
Remote Activity Reporting enabled
Remote Office Alarms enabled
Information below is a Release 3 example
Far End Terminal Lucent Technologies
Remote Activity Reporting enabled
Remote Office Alarms enabled
*/
;

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lucent Technologies FT-2000 OC-48 and is the answer not in the manual?

Lucent Technologies FT-2000 OC-48 Specifications

General IconGeneral
BrandLucent Technologies
ModelFT-2000 OC-48
CategoryNetwork Hardware
LanguageEnglish