EasyManua.ls Logo

Lucent Technologies FT-2000 OC-48 - Page 775

Lucent Technologies FT-2000 OC-48
1578 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Craft Interface Terminal Usage
Issue 8.0 July 2002
11-67
Release 2 (Use the SECURITY category.)
The above report shows that access to a remote location over the data
communications channel (DCC) is enabled (access is allowed). This report is not
available at a repeater site.
The fields of the report are described below:
DCC Address - Shows the access identifier of the SONET data communications
channel.
Far End
Terminal
- Shows the far-end terminal manufacturer, "Lucent
Technologies" or "Other."
Remote
Activity
Reporting
- Shows that remote reporting is enabled or disabled. For
example, when enabled, far-end activity is indicated by the FE
ACTY LED being lit and reported in the Retrieve-Network Alarms
Report.
Remote
Office
Alarms
- Shows that the remote office alarms are allowed to be displayed
locally (enabled) or not (disabled). For example, when disabled,
only local office alarms are reported locally.
Far End TBOS - Shows that the far-end parallel telemetry (TBOS) is allowed to
be displayed locally (enabled) or not (disabled).
Lucent Technologies-FT-2000 96-07-19 23:15:15 EST
M Retrieve-Far End Communications:DCC: COMPLD
/* Far End Communication Configuration Report
======================================================================
Far Remote Remote Far
DCC End Activity Office End
Address Terminal Reporting Alarms TBOS
======================================================================
dcc Lucent Technologies enabled disabled enabled
*/

Table of Contents