Craft Interface Terminal Usage
11-44 Issue 8.0 July 2002
Example 4 - CONFIGURATION-Retrieve-Attribute-Alarm 11
Releases 2 and Later
These reports show the provisioned delay values of the alarm attributes at the
FT-2000 OC-48 Lightwave System level.
Incoming
Signal Alarm
Delay
- Shows how many seconds the FT-2000 end terminal
will wait after declaration of an incoming signal defect
before activating all indicators.
Alarm Clear
Delay
- Shows how many seconds the FT-2000 end terminal
will wait after the alarm retires before reporting it to the
external maintenance interfaces (for example, user
panel, operations systems).
Protection
Access
Availability
- The alarm level associated with the "protection access
unavailable" condition.
Tributary
Reporting
- The alarm level associated with the "tributary failed"
condition.
Lucent Technologies-FT-2000 96-07-19 23:15:15 EST
M Retrieve-Attribute-Alarm: COMPLD
/* System Alarm Attributes Report
=============================================================
Parameter Value
=============================================================
Incoming Signal Alarm Delay 20
Alarm Clear Delay 20
Protection Availability NO
Tributary Reporting NO
*/
;

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lucent Technologies FT-2000 OC-48 and is the answer not in the manual?

Lucent Technologies FT-2000 OC-48 Specifications

General IconGeneral
BrandLucent Technologies
ModelFT-2000 OC-48
CategoryNetwork Hardware
LanguageEnglish