Craft Interface Terminal Usage
11-120 Issue 8.0 July 2002
The fields of the report are described below:
Address - Shows the specific OC-48 line.
Bin - Shows the quarter-hour (QH) and the day bins.
TCA Report - Shows if the automatic reporting of TCAs is enabled or
disabled.
BER - Shows the provisioned bit error rate for the QH and day bins
that will cause a TCA.
CV-S - Shows the provisioned number of code violations for the QH
and day bins that will cause a TCA.
ES-S - Shows the provisioned number of errored seconds for the QH
and day bins that will cause a TCA.
SES-S - Shows the provisioned number of severely errored seconds
for the QH and day bins that will cause a TCA.
SEFS-S - Shows the provisioned number of section errored frame
seconds for the QH and day bins that will cause a TCA.
TCA Report - Shows if the automatic reporting of TCAs is enabled or
disabled.