NTP-015: Circuit Order 365-575-102
Page4of6 Issue8.0,July2002
11. Look at the report, verify that the protection
quad slots do not appear in the cross-connect
column. If a cross-connection is shown, then
traffic is possible at the quad.
Is there a cross-connection shown for any of the
four required protection slots?
If YES, then consult with your supervisor
and make certain that the quad specified in
the work order is correct, is to be used as
the protection link, and that the quad is not
currently supporting traffic. If the quad is
supporting traffic, then – either a different
quad must be selected or the traffic must be
moved. STOP! You cannot re-start this
procedure until this issue is resolved.
If NO, then continue with Step 12.
—
12. Delete the DS3/STS-1E Low Speed Ports and
remove the circuit pack(s). Execute the
Configuration-Update command.
Circuit Order: NTP-003
13. Delete all existing cross-connection(s) for the
new protection quad slots, if not already
performed.
DLP-536
14. Continue with Step 19.
15. Are fibers already terminated on the OC-3/IS-3
circuit pack?
If NO, then it is available, go to Step 18.
If YES, then continue with Step 16.
—
16. Determine whether the quad already has
cross-connects defined. At the CIT, select the
CONFIGURATION-Retrieve-Crossconnect
ion-All command for this slot.
—
DOITEMSBELOWINORDERLISTED........ FORDETAILS,GOTO

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lucent Technologies FT-2000 OC-48 and is the answer not in the manual?

Lucent Technologies FT-2000 OC-48 Specifications

General IconGeneral
BrandLucent Technologies
ModelFT-2000 OC-48
CategoryNetwork Hardware
LanguageEnglish