TAP-102: Trouble Clearing 365-575-102
Page6of8 Issue8.0,July2002
Table A - Trouble Conditions (Contd)
Description Go To TAP
non-preemptible protn access TAP-114
OC3 auto switch at far end TAP-115
OC3 auto switch at near end TAP-115
OC3 forced switch at far end TAP-114
OC3 forced switch at near end TAP-114
OC3 INTFC failure TAP-111
OC3 INTFC removed TAP-112
OC3 inhibit at near end TAP-114
OC3 lockout at far end TAP-114
OC3 lockout at near end TAP-114
OC3 loopback (from OC3) TAP-114
OC3 loopback (from OC48) TAP-114
OC3 mode conflict (equipment) TAP-158
OC3 mode conflict (slot pair) TAP-158
OC3 mode conflict (x-connect) TAP-158
OC12 auto switch at far end TAP-115
OC12 auto switch at near end TAP-115
OC12 forced switch at far end TAP-114
OC12 forced switch at near end TAP-114
OC12 INTFC failure TAP-111
OC12 INTFC removed TAP-112
OC12 inhibit at near end TAP-114
OC12 lockout at far end TAP-114
OC12 lockout at near end TAP-114
OC12 loopback (from OC48) TAP-114
OHCTL failure TAP-111
OHCTL removed TAP-112
optical parameter out-of-range TAP-135
Continued on next page