365-575-102 TroubleClearing:
Issue 8.0, July 2002 Page 1 of 2
TAP-106
Address 'TL-1 Link Failure'
1. Does the Active Alarms and Status Report show a controller failure (LNCTL,
OHCTL, or SYSCTL circuit pack)?
If YES, then go to TAP-102.
If NO, then continue with Step 2.
2. Initiate a Trouble Report to the responsible Operations System stating an
incoming TL1 link failure has been detected on this network.
3. STOP! YOU HAVE COMPLETED THIS PROCEDURE.