365-575-102 TroubleClearing:
Issue 8.0, July 2002 Page 1 of 8
TAP-115
Clear Automatic Switch Condition
Overview: This procedure is used to clear one of the following automatic protection
switch conditions:
line auto switch sync mode auto switch
LS auto switch sync reference auto switch
OC3 auto switch at far end TG auto switch.
OC3 auto switch at near end OC12 auto switch at far end
OC12 auto switch at near end
1. Whichswitchistobecleared?
If TG auto switch,thencontinuewithStep2.
If LS auto switch,thencontinuewithStep8.
If sync mode auto switch, then continue with Step 14.
If sync reference auto switch, then continue with Step 14.
If line auto switch, then continue with Step 17.
If OC3 auto switch at near end, then continue with Step 29.
If OC3 auto switch at far end, then continue with Step 29.
If OC12 auto switch at near end, then continue with Step 29.
If OC12 auto switch at far end, then continue with Step 29.
TG Auto Switch Condition
2. Is there one or more other conditions with the same TG Source Address in
the report?
NOTE:
Conditions are shown in the Description column of the Active Alarms
and Status Report.
If YES, then continue with Step 3.
If NO, then continue with Step 5.
3. Identify the topmost other condition in the report with the same TG Source
Address. Find this condition in Table A of TAP-102 and go to the referenced
TAP.
4. STOP! YOU HAVE COMPLETED THIS PROCEDURE.