365-575-102 TroubleClearing:
Issue 8.0, July 2002 Page 1 of 2
TAP-132
Clear ‘Incoming OC-48 APS Byte Fail’
NOTE:
This condition is associated with a signal degrade (SD) or an automatic
protection switch (APS) channel failure on the protection line.
1. At the CIT, select FAULT-Retrieve-Alarm to obtain an Active Alarms and Sta-
tus Report.
2. Is the incoming OC-48 SD condition shown on the report for the protection
line?
If YES, then go to TAP-110.
If NO, then continue with Step 3.
3. Is the APS channel failure condition shown on the report for the protection
line?
If YES, then go to TAP-105.
If NO, then go to TAP-108.