365-575-102 Trouble Clearing: TAP-174
Issue 8.0, July 2002 Page 7 of 8
33. Does the incoming (from OC-48) STS LOP condition still appear in the
Active Alarm and Status Report?
If YES, then go to Step 30.
If NO, then continue with Step 35.
34. At the local node, select FAULT-Switch-Line:Reset command and exe-
cute to normalize the line identified in Step 3 (original line now active.)
35. STOP! YOU HAVE COMPLETED THIS PROCEDURE.