365-575-102 Detailed Level Procedure: DLP-536
Issue 8.0, July 2002 Page 5 of 8
17. Do you have instructions pertaining to cross-connections at other network ele-
ments?
If YES, then continue with Step 18.
If NO, then continue with Step 22.
18. Establish a remote login to one of the other network elements in the FT-2000
ring network.
Reference: DLP-524
19. Repeat Steps 3 through 22 for the appropriate cross-connections. Do not for-
get that the remote node has now become the local node.
20. Discontinue the remote login.
Reference: DLP-524
21. Repeat Steps 18 through 20 for each of the remaining network elements in the
ring network that requires cross-connections per the instructions.
22. All cross-connections have been made and the FT-2000 ring network is now
ready for traffic and/or testing.
23. STOP! YOU HAVE COMPLETED THIS PROCEDURE.