Administration and Provisioning
Issue 8.0 July 2002
8-53
â–  At node 2, a 1-way drop cross-connection is entered by specifying:
— Source (tributary)
— Source line (line 1W)
— Source STS-3 tributary (tributary 6)
— Source STS-1 tributary (tributary 1)
— Source node TID† (node 0 TID)
— Destination (STS-1 port)
— Destination low-speed interface slot* (slot 5A)
— Destination low-speed port (1).
â–  At node 2, a 2-way add/drop cross-connection is entered by specifying:
— Source (STS-1 port)
— Source low-speed interface slot* (slot 2A)
— Source low-speed port (3)
— Destination line (line 1E)
— Destination STS-3 tributary (tributary 5)
— Destination STS-1 tributary (tributary 2)
— Destination node TID† (node 3 TID).
â–  The same 2-way add/drop cross-connection may also be entered by
specifying:
— Source (tributary)
— Source line (line 1E)
— Source STS-3 tributary (tributary 5)
— Source STS-1 tributary (tributary 2)
— Source node TID† (node 3 TID)
— Destination (STS-1 port)
— Destination low-speed interface slot* (slot 2A)
— Destination low-speed port (3).

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lucent Technologies FT-2000 OC-48 and is the answer not in the manual?

Lucent Technologies FT-2000 OC-48 Specifications

General IconGeneral
BrandLucent Technologies
ModelFT-2000 OC-48
CategoryNetwork Hardware
LanguageEnglish