Administration and Provisioning
Issue 8.0 July 2002
8-83
â–  At node 2, the following is also entered:
— Type (2-way)
— Line (line 1E)
— STS-3 tributary (tributary 6)
— STS-1 tributary (tributary 3)
— Source node TID
*
(node 3 TID).
â–  At node 3, STS-1 squelch map information is entered by specifying:
— Type (2-way)
— Line (line 1W)
— STS-3 tributary (tributary 6)
— STS-1 tributary (tributary 3)
— Source node TID* (node 0 TID).
NOTE:
While cross-connections are entered, the FT-2000 OC-48 Add/Drop-Rings
Terminal will report several trouble conditions (for example, circuit
provisioning error and path integrity failure. However,
these trouble conditions should be ignored until all the cross-connections
for a circuit have been entered. If the trouble conditions remain after all the
cross-connections have been entered, refer to the "Operation and
Maintenance (TOP)" section (Volume II).
For more information about entering limited STS-1 cross-connections at an
FT-2000 OC-48 Add/Drop-Rings Terminal, refer to the Operation Task Index in the
"Operation and Maintenance (TOP)" section (Volume II).
* Entering a question mark (?) in response to the TID prompt will display a point-and-shoot
list of available addresses in the ring network. Enter the Retrieve-Map-Ring input to
update the point-and-shoot list.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lucent Technologies FT-2000 OC-48 and is the answer not in the manual?

Lucent Technologies FT-2000 OC-48 Specifications

General IconGeneral
BrandLucent Technologies
ModelFT-2000 OC-48
CategoryNetwork Hardware
LanguageEnglish