Administration and Provisioning
Issue 8.0 July 2002
8-95
Table 8-2. FT-2000 OC-48 Add/Drop-Rings Terminal Output Values
Entity Values
TID 1 to 20 alphanumeric characters
NID
*
0-15
Filename 1 to 8 alphanumeric characters
User-Login 1 to 10 alphanumeric characters
provisionedcontrlpt 1 to 26 alphanumeric characters
provisionedenvironmentalpt 1 to 26 alphanumeric characters
System system
Line line-{all,1e,1w}
Slot (TRMTR) trmtr-{all,1e,1w}
Slot (RCVR) rcvr-{all,1e,1w}
Slot (LS INTFC) ls-{all,1a-8b,p1,p2}
Slot (TG) tg-{all,1,2}
Slot (LSSW) lssw-{all,out,in}
Slot (SYSCTL) sysctl
Slot (SYSMEM) sysmem
Slot (LNCTL) lnctl-{1w}
Slot (OHCTL) ohctl-{all,1e,1w}
Slot (TOHCTL)
§ tohctl
Port (DS3) ls-{all,1a-8b}-{all,1-3}
Port (EC1)
ls-{all,1a-8b}-{all,1-3}
Port (OC3) ls-{all,1a-8b}
Port (IS3) ls-{all,1a-8b}
Port (OC12) ls-{all,1b,3b,5b,7b}
Port (STS-1) ls-{all,1a-8b}-{all,1-3}
Port (TIMING OUT) DS1-out-{all,1,2}
Port (TIMING IN) DS1-in-{all,pri,secy},
OC48-in-{1e,1w}
Port (COM)
§
{dce,dte,dcc,x25}
Quad (LS INTFC) ls-{all,1b,3b,5b,7b}
Operations Interface (User Panel) user panel
Operations Interface (CIT) cit-{dce,dte,dcc}
tl1-{dce,dte,dcc,x25}
Operations Interface (UID) <User-Login>
Operations Interface (DCC-OC48) dcc48-{all,1e,1w}
Operations Interface (DCC-OC3) dcc3-{all,1a-8b}
Operations Interface (DCC-OC12) dcc12-{all,1b,3b,5b,7b}
Shelf shlf-{1e,1w}-hs
shlf-ls
Operations Interface (MISC DSCRT 1) misc dscrt1
Operations Interface (MISC DSCRT 2) misc dscrt2
See footnotes at end of table.