Administration and Provisioning
8-110 Issue 8.0 July 2002
- "CR": critical
-"MJ":major
- "MN": minor
- "NA": status not alarmed
- "NR": status not alarmed and not reported to the OS.
— The Description parameter is the text string associated with the
selected miscellaneous discrete environmental input point. It is a
character string of up to 26 characters, where the characters are
letters, digits, or spaces. It is used to identify the point in the
Retrieve-History and Retrieve-Alarm (and Status)
reports. In Release 5, the number 1, 2, 3, and 4 inputs are reserved
for the following alarms from an FT-Lightwave Booster Amplifier.
â–  CONFIGURATION-Set-Date (TL1 = ED-DAT): This input sets the network
element clock date and time and provisions automatic daylight savings
time processing.
— The Date parameter sets the current date in the network element
clock. It is entered in the form YY-MM-DD where:
— The Hours parameter sets the hour (0 to 23) in the network element
clock. A value of "zero" may be entered as "−0", "0", or "+0". These
entries are treated as the same value.
— The Minutes parameter sets the minute (0 to 59) in the network
element clock. A value of "zero" may be entered as "−0", "0", or "+0".
These entries are treated as the same value.
— The Seconds parameter sets the second (0 to 59) in the network
element clock. A value of "zero" may be entered as "−0", "0", or "+0".
These entries are treated as the same value.
— The Standard Time Zone parameter is the 3-letter string (for
example, EST, MST) that is indicated as part of the date and time
stamp in command responses when Standard Time is in effect.
FT-LBA Miscellaneous
Discrete
FT-2000 Environmental
Input Suggested Text
Fuse/Power Alarm 1 FT-LBA fuse/power failure
Fan Alarm 2 FT-LBA fan failure
1EW (Service) Failure 3 FT-LBA 1EW failure
1WE (Service) Failure 4 FT-LBA 1WE failure
- YY is the year (00-99)
- MM is the month (1-12)
- DD is the day (1-31).

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lucent Technologies FT-2000 OC-48 and is the answer not in the manual?

Lucent Technologies FT-2000 OC-48 Specifications

General IconGeneral
BrandLucent Technologies
ModelFT-2000 OC-48
CategoryNetwork Hardware
LanguageEnglish