Administration and Provisioning
8-138 Issue 8.0 July 2002
Interfaces" or Volume I, Section 10, "Technical Specifications" for information
about minimum CIT requirements.)
â–  CONFIGURATION-Set-Attribute-Environment: This input reports
the Alarm Level and Description parameters for each selected
miscellaneous discrete environmental input point. The Description
parameter is used to identify the point in the Retrieve-History and
Retrieve-Alarm (and Status) reports. The Alarm Level parameter
provisions the severity of the condition associated with the closing of the
selected miscellaneous discrete environmental input point. For repeater
applications the only choice is "MN" (minor).
— The Point parameter selects the miscellaneous discrete
environmental input point(s) to include in the report.
— The Alarm Level parameter provisions the severity of the condition
associated with the closing of the selected miscellaneous discrete
environmental input point. For repeater applications, the only choice
is "MN" (minor).
— The Description parameter provisions the text string associated with
the selected miscellaneous discrete environmental input point. It is a
character string of up to 26 characters, where the characters are
letters, digits, or spaces. It is used to identify the environmental point
in the Retrieve-Alarm (and Status) and
Retrieve-History reports.
â–  CONFIGURATION-Set-Date: This input sets the network element clock
date and time and provisions automatic daylight savings time processing.
— The Date parameter sets the current date in the network element
clock. It is entered in the form YY-MM-DD where:
— YY is the year (00-99)
— MM is the month (1-12)
— DD is the day (1-31)
— The Hours parameter sets the hour (0 to 23) in the network element
clock.
— The Minutes parameter sets the minute (0 to 59) in the network
element clock.
— The Seconds parameter sets the second (0 to 59) in the network
element clock.
— The Standard Time Zone parameter is the 3-letter character string
(for example, EST, MST) that is indicated as part of the date and
time stamp in command responses when Standard Time is in effect.
— The Start Daylight Savings Date parameter sets the date when the
network element moves the current time forward by 1 hour. It should
be entered in the form MM-DD where:
— MM is the month (1-12)

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lucent Technologies FT-2000 OC-48 and is the answer not in the manual?

Lucent Technologies FT-2000 OC-48 Specifications

General IconGeneral
BrandLucent Technologies
ModelFT-2000 OC-48
CategoryNetwork Hardware
LanguageEnglish