Maintenance Description
Issue 8.0 July 2002
9-11
â–  Serial telemetry (TBOS) alarm and scan points (Releases 1 through 4.0
only)
â–  TL1 command response messages
â–  Abnormal (ABN), near-end activity (NE ACTY), far-end activity (FE ACTY),
alarm cutoff/locator (ACO/LOCTR), line locator (LINE LOCTR), USE CIT,
and POWER ON LEDs on the user panel.
The incoming signal alarm delay only applies to autonomous indications of the
following incoming signal conditions:
â–  inc.(from DS1) sync ref fail
â–  inc.(from OC48) path RFI/yellow
â–  inc.(from OC48) sync ref fail
â–  inc.(from STSX) line RFI/yellow
â–  incoming (from DSX) DS3 LOS
â–  incoming (from DSX) DS3 SD
â–  incoming (from OC-48) DS3 AIS
â–  incoming (from OC-48) DS3 LOF
â–  incoming (from OC-48) path AIS
â–  incoming (from OC-48) STS LOP
â–  incoming (from STSX) EC1 LOF
â–  incoming (from STSX) EC1 LOP
â–  incoming (from STSX) EC1 LOS
â–  incoming (from STSX) EC1 SD
â–  incoming (from STSX) line AIS
â–  incoming (from STSX) path AIS*
â–  incoming OC-3 AIS
â–  incoming (from OC-3) path AIS*
â–  incoming OC-3 APS byte fail
â–  incoming OC-3 line RFI/yellow
â–  incoming OC-3 LOF
â–  incoming OC-3 LOS
â–  incoming OC-3 SD
â–  incoming OC-3 SF
â–  incoming OC-48 AIS
â–  incoming OC-48 APS byte fail

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lucent Technologies FT-2000 OC-48 and is the answer not in the manual?

Lucent Technologies FT-2000 OC-48 Specifications

General IconGeneral
BrandLucent Technologies
ModelFT-2000 OC-48
CategoryNetwork Hardware
LanguageEnglish