Craft Interface Terminal Usage
Issue 8.0 July 2002
11-49
Only one status condition is reported in order of precedence as shown below:
Not Cross-Connected - The selected slot is not cross-connected in the drop
direction.
Unavailable - The topology is not available at the local node (for
example, the ring is incomplete/open), all or part of
the cross-connection table is missing, or circuit audit
is suspended.
Path Integrity Failure - The circuit path is open.
Squelch Map
Inconsistent
- The circuit audit algorithm has declared an STS1
Squelch Map Inconsistent condition for this circuit.
Circuit Provisioning
Error
- The circuit audit algorithm has declared a Circuit
Provisioning Error condition for this circuit.
audit disabled - One or more of the cross-connections which make up
the circuit has its AUDIT parameters set to NO.
good - No errors were detected.
Report parameters are:
Source AID - The STS-1 tributary or port address identifier.
Destination AID - The STS-1 tributary or port address identifier.
Ring Direction - The circuit path direction as specified in the
command.
Primary State - The status of 1WAYDRI and 1+1 protected OC-3
interface cross-connections.
Audit - The cross-connection AUDIT parameter.