The fields of the report are described below:
Status: - Shows the circuit (path) status in order of precedence as
shown below:
Not Cross-Connected - The slot is not cross-connected in the drop direction.
Unavailable - The ring topology is not available at the local node (for
example, the ring is incomplete/open), all or part of the
cross-connection table is missing, or circuit audit is
suspended.
Path Integrity
Failure
- The circuit path is open.
Squelch Map
Inconsistent
- The circuit audit algorithm has declared an STS3 Squelch
Map Inconsistent condition for this circuit.
Circuit Provisioning
Error
- The circuit audit algorithm has declared a Circuit
Provisioning Error condition for this circuit.
good - No errors were detected.
At Node: - Shows the target identifier (TID) of the node where the
report is requested (topmost entry).
West - Shows the selected line and tributary, or slot.
Cross-Connect - Shows the active and/or standby cross-connection,
direction arrow, and a question mark (?) for an open
circuit (path).
East - Shows the selected line and tributary, or slot.
Ring Direction - Shown by the caret (^) for all nodes except for the local
node.