Craft Interface Terminal Usage
Issue 8.0 July 2002
11-55
The fields of the report are described below:
Destination
/Source
- Shows the target identifier (TID) and may be either the
destination node or the source node. A dash is shown when a
tributary is not cross-connected. A question mark is shown
when a tributary An asterisk is shown for invalid TID/NID pairs.
Cross-
Connection
- Shows the line, direction (West is left, East is right), and
tributary number where the STS3 signal is
added/dropped/through connected in this network element.
Active cross-connection is shown by dashes (---) whereas a
standby cross-connection is shown by periods (...).
Source/Dest
ination
- Shows the target identifier (TID) and may be either the source
node or the destination node. A dash is shown when a tributary
is not cross-connected. A question mark is shown when a
tributary is cross-connected to an incorrect Source/Destination
TID. An asterisk is shown for invalid TID/NID pairs.