Craft Interface Terminal Usage
11-90 Issue 8.0 July 2002
The fields of the report are described below:
Address - Shows the OC-48 line, DS3 circuit pack slot, and port of the
STS-1 path.
Parameter
Value
- Shows the status, the actual received data string (ActRx), the
provisioned received (PrvRx), and/or transmit (PrvTx) data
strings.
ActRx - Shows the actual incoming STS-1 data string for the specified
port.
PrvRx - Shows the expected incoming STS-1 data string for the
specified port.
PrvTx - Shows the provisioned outgoing STS-1 data string for the
specified port.
Status - Shows the ActRx (actual received) data string as follows:
good means ActRx path is the same as PrvRx path.
MISMATCH means ActRx path is different than PrvRx path.
NOT APPLICABLE means the addressed slot is in the AUTO
state or is not equipped with a DS3 circuit pack.
UNAVAILABLE means that there is an incoming OC-48 line
failure, a missing slot cross-connection, or an unprotected
failure.
Label - Shows the C2 byte value in hexadecimal code for the received
path signal and a corresponding text description of the STS
payload type.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lucent Technologies FT-2000 OC-48 and is the answer not in the manual?

Lucent Technologies FT-2000 OC-48 Specifications

General IconGeneral
BrandLucent Technologies
ModelFT-2000 OC-48
CategoryNetwork Hardware
LanguageEnglish