Craft Interface Terminal Usage
Issue 8.0 July 2002
11-113
The fields of the report are described below:
Address - Shows the specific slot and port for the EC-1 line.
Bin - Shows the quarter-hour (QH) and day bins.
Section
SEFS-S
- Shows the provisioned number of section severely errored frame
seconds for the QH bin and the day bin that will cause a TCA.
BER - Shows the provisioned bit error rate; for example, -9 is 10
-9
,forthe
QH bin and day bin.
CV-L - Shows the number of line code violations reported during the
specified time that exceeded the BER setting.
ES-L - Shows the provisioned number of line errored seconds for the QH
bin and the day bin that will cause a TCA.
SES-L - Shows the provisioned number of line severely errored seconds
for the QH bin and the day bin that will cause a TCA.
UAS-L - Shows the provisioned number of unavailable seconds for the QH
bin and the day bin that will cause a TCA.
TCA
Report
- Shows if the automatic reporting of TCAs is enabled or disabled.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lucent Technologies FT-2000 OC-48 and is the answer not in the manual?

Lucent Technologies FT-2000 OC-48 Specifications

General IconGeneral
BrandLucent Technologies
ModelFT-2000 OC-48
CategoryNetwork Hardware
LanguageEnglish