Craft Interface Terminal Usage
Issue 8.0 July 2002
11-139
The following example shows how a manual switch condition is displayed at the
node where the manual switch is initiated.
The following example shows what is displayed at the node located at the
opposite end of the line being switched.
The following example shows what is displayed at the remaining node(s) on the
ring network.
----------------------------------------------------
trmtr-1e TRMTR active manual-ring
trmtr-1w TRMTR standby manual-ne
----------------------------------------------------
rcvr-1e RCVR active manual-ring
rcvr-1w RCVR standby manual-ne
-------------------------------------------------------
trmtr-1e TRMTR standby manual-fe
trmtr-1w TRMTR active manual-ring
-------------------------------------------------------
rcvr-1e RCVR standby manual-fe
rcvr-1w RCVR active manual-ring
-----------------------------------------------------
trmtr-1e TRMTR active manual-ring
trmtr-1w TRMTR active manual-ring
-----------------------------------------------------
rcvr-1e RCVR active manual-ring
rcvr-1w RCVR active manual-ring