Setting up Compax3 C3F_T40
146 192-121102 N04 June 2008
Force feedforward
For the force control with pumps and pressure valves, the control signal is,
differently from the control with path valves, proportional to the actual pressure
value for dynamic control the integrator is not sufficient in order to generate the
static component of the control variable.
This requires the force feedforward (KFs).
Main axis: Object 2250.23
auxiliary axis: Object 2251.23
KFs (%/N) or(%/bar/PSI), a defined component of the force build-up is built up in
a controlled manner.