EasyManuals Logo

Parker Compax3 Fluid T40 User Manual

Parker Compax3 Fluid T40
470 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #454 background imageLoading...
Page #454 background image
Specifications
C3F_T40
454 192-121102 N04 June 2008
Technical data
Motion control with motion profiles, suitable for position and force/pressure control
for up to 2 axes.
Command value generator
Jerk-limited ramps.
Travel data in increments, mm, inch.
Specification of speed, acceleration, delay and jerk factor.
Force/pressure data in N, bar, psi.
Monitoring functions
Voltage range.
Following error monitoring.
Hard and Software limit switch
Technology functions of servo controllers
IEC61131-3 programs in the servo controller (T30)
Cam function in the servo controller (T40)
Voltage supply 24VDC
Controller type Compax3 F001 D2
Voltage range
21 - 27VDC
Mains module
with switch-on current limitation, due to
capacitive load
Fuse
MTP miniature circuit breaker or "delayed action
fuse", due to capacitive load
Current drain of the device
0.8A (max. 1.5A)
Total current drain
0.8A + total load of the digital outputs
Ripple
<1Vss
Requirement according to safe extra
low voltage (SELV)
yes
Size / weight
Controller type Compax3 F001 D2
Dimensions: HxWxD [mm]
199x80x130
Weight [kg]
2.0
Housing / protection class
Enclosed metal housing, insulation according to
EN60529 / IP 20
12. Specifications

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Parker Compax3 Fluid T40 and is the answer not in the manual?

Parker Compax3 Fluid T40 Specifications

General IconGeneral
SeriesCompax3
Power Supply Voltage24 VDC
Output Current40A
Protection ClassIP20
CommunicationCANopen, RS232
Operating Temperature0°C to +45°C
Relative Humidity5 to 95 %, non-condensing
Storage Temperature-25 to +70 °C