Compax3 Accessories C3F_T40
452 192-121102 N04 June 2008
11.8 CAN - plug BUS10/01
We offer a CAN plug and special cable in any length to order for the CAN-bus
wiring:
CAN cable: SSL02/.. not prefabricated (colour according to DESINA).
CAN plug: BUS10/01 with 2 cable inputs and screw terminals as well as a switch
for activating the terminal resistor.
The terminal resistor must be activated on the first and on the last station
(=switch setting ON).
Note for integrated C3 powerPLmC (Compax3 interface designation "C1x")
The CAN bus of the C3 powerPLmC does already contain a terminal resistor.
Therefore it applies for the C3 powerPLmC:
Put switch to OFF
wire C3 powerPLmC always at the end of the CAN bus!
CAN wiring
Schaltbild
Circuit Diagram
Kabel abisolieren
Cable stripping
CAN-GND 1
CAN-L 2
CAN-H 3
CAN-L 4
CAN-H 5
CAN-GND 6
2
1
6
3
5
4
7
8
9
ON
OFF
ON
OFF
R1
120 Ohm
0,25W
S1
Kabelschirm
Shielding on cable
Shielding on housing
Gehäuseschirm
Printklemme
Print terminal
X1
X2
Federleiste
D-Sub female
10mm 7mm
max.
5mm

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Parker Compax3 Fluid T40 and is the answer not in the manual?

Parker Compax3 Fluid T40 Specifications

General IconGeneral
SeriesCompax3
Power Supply Voltage24 VDC
Output Current40A
Protection ClassIP20
CommunicationCANopen, RS232
Operating Temperature0°C to +45°C
Relative Humidity5 to 95 %, non-condensing
Storage Temperature-25 to +70 °C

Related product manuals