ENERGY SAVER MODES
2-128
A229 SM
2.11.3 LOW POWER MODE
Entering low power mode
The low power shift timer runs out after the end of a job.
What happens in low power mode
The fusing lamp drops to a certain temperature, that depends on the setting of
SP5-920 (the default is 177
°
C). The other conditions are the same as for energy
saver mode.
Return to stand-by mode
The machine returns to standby mode in exactly the same way as from energy
saver mode.
The recovery time from low power mode depends on the setting of SP5-920. The
default (from 177
°
C) is about 20 seconds.
Recovery
Time
Operation
Switch
Energy
Saver LED
Fusing
Temp.
System
+5V
Main Power
LED
About
20 seconds
On On
177
°
C
On On