EasyManuals Logo

Risco ProSYS series User Manual

Risco ProSYS series
232 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #201 background imageLoading...
Page #201 background image
ProSYS Installation and Programming Manual 201
Zone Expansion Module: 16-Zone
Current Consumption
27 mA, typical / 45 mA, maximum
Main Panel Connection
4-wire BUS, up to 300 m from Main Panel
Dimensions
16.5 cm x 6.6 cm x 1.8 cm
BUS Zone Expansion Module
Current Consumption
20 mA, typical
Main Panel Connection
4-wire BUS, up to 300 m from Main Panel
Dimensions
10.5 cm x 6.6 cm x 1.8 cm
Wireless Expansion Modules 8-/16-Zone
Current Consumption
40 mA , maximum
Frequency
868.6-868.7 MHz (narrowband operation in EU) or 433.92 MHz
Dimensions
14.5 cm x 9 cm x 3.8 cm
Utility Output Expansion Module: 4-Output
Current Consumption
25 mA, typical / 140 mA, maximum
Contacts
4 Form C (SPDT) Relays
Contact rating: 5 A / 24V DC
Main Panel Connection
4-wire BUS, up to 300 m from Main Panel
Dimensions
10.5 cm x 6.6 cm x 2.2 cm
Utility Output Expansion Module: 8-Output
Current Consumption
25 mA, typical / 30 mA, maximum
Contacts
Open Collector, Active Pull-Down, 70 mA, maximum
Main Panel Connection
4-wire BUS, up to 300 m from Main Panel
Dimensions
10.5 cm x 6.6 cm x 1.8 cm
1.5 Power Supply Expansion Module
Input Power
16.5 Volts AC @ 40 VA (via transformer)
Max Current
Consumption
180mA
Rechargeable Standby
Battery
12 Volts up to 17 Amp-Hours (AH), typical
Maximum charging time
24 hours
Power Outputs:
Bell/LS (External)
Auxiliary Power: 12 Volts DC @ up to 1.5A*
Bell/LS (External) Sounder Output:12 Volts DC @ 900 mA,
maximum
*: Total current Bell+Aux=1.5A
Fuses F1: Battery power 3.0 A
F2: Auxiliary power 2.0 A
F3: Bell/loudspeaker power 1.0 A
Main Panel Connection
4-wire BUS, up to 300 m from Main Panel

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Risco ProSYS series and is the answer not in the manual?

Risco ProSYS series Specifications

General IconGeneral
CommunicationIP, GSM, PSTN
Wireless ProtocolTwo-way wireless
Battery BackupYes
Remote ControlYes, via app
IntegrationRISCO Cloud

Related product manuals