ProSYS Installation and Programming Manual 201
Zone Expansion Module: 16-Zone
Current Consumption
27 mA, typical / 45 mA, maximum
Main Panel Connection
4-wire BUS, up to 300 m from Main Panel
Dimensions
16.5 cm x 6.6 cm x 1.8 cm
BUS Zone Expansion Module
Current Consumption
20 mA, typical
Main Panel Connection
4-wire BUS, up to 300 m from Main Panel
Dimensions
10.5 cm x 6.6 cm x 1.8 cm
Wireless Expansion Modules 8-/16-Zone
Current Consumption
40 mA , maximum
Frequency
868.6-868.7 MHz (narrowband operation in EU) or 433.92 MHz
Dimensions
14.5 cm x 9 cm x 3.8 cm
Utility Output Expansion Module: 4-Output
Current Consumption
25 mA, typical / 140 mA, maximum
Contacts
4 Form C (SPDT) Relays
Contact rating: 5 A / 24V DC
Main Panel Connection
4-wire BUS, up to 300 m from Main Panel
Dimensions
10.5 cm x 6.6 cm x 2.2 cm
Utility Output Expansion Module: 8-Output
Current Consumption
25 mA, typical / 30 mA, maximum
Contacts
Open Collector, Active Pull-Down, 70 mA, maximum
Main Panel Connection
4-wire BUS, up to 300 m from Main Panel
Dimensions
10.5 cm x 6.6 cm x 1.8 cm
1.5 Power Supply Expansion Module
Input Power
16.5 Volts AC @ 40 VA (via transformer)
Max Current
Consumption
180mA
Rechargeable Standby
Battery
12 Volts up to 17 Amp-Hours (AH), typical
Maximum charging time
24 hours
Power Outputs:
Bell/LS (External)
Auxiliary Power: 12 Volts DC @ up to 1.5A*
Bell/LS (External) Sounder Output:12 Volts DC @ 900 mA,
maximum
*: Total current Bell+Aux=1.5A
Fuses F1: Battery power 3.0 A
F2: Auxiliary power 2.0 A
F3: Bell/loudspeaker power 1.0 A
Main Panel Connection
4-wire BUS, up to 300 m from Main Panel