STRASBAUGH, INC.
3-8 February 19, 2002 7AF SECS/GEM Interface Ver. 1.9
Strasbaugh Confidential
9. An arrow directly into a super-state to the C (conditional) symbol describes a transition to a particular sub-state
based on some other relevant data. The conditional data is not represented in the diagram but is described in the
associated text.
3.10 Modifying Equipment Constants from the 7AF Console
The following steps should be taken to modify an Equipment Constant from the 7AF Console:
1. Exit the 7AF application and to return to the DOS prompt.
2. Using a text editor, such as EDIT, open the file EC_DEFLT.TXT.
3. This file contains several lines of text, each line containing the VID of an Equipment Constant, and that EC’s
current setting. Refer to Appendix A of this document to determine the VID of the Equipment Constant that you
want to modify.
4. Using the text editor, modify the current setting field of the Equipment Constant, indexed my VID.
5. Save the file EC_DEFLT.TXT.
6. Reboot the 7AF computer to restart the 7AF application.