Atmospheric Single-Arm Robot Manual
4000-0016 Rev A
17
Robot Cables
If you replace a cable or move the robot cables, inspect it to make sure all
connector screws are tightly connected. If there is excess cable, the
following steps are recommended to reduce the noise level and protect
against electro-magnetic interference (EMI).
1.
Fold the excess length as shown here:
2. Tightly gather the loops of cable and tie with three cable ties:
3. Press the gathered cable against the metal robot chassis. Pack the
cable tightly against the chassis.
Safety Labels
Hazards to personnel include electric shock, burns, collision with a
moving robot, and laser radiation.
Damage to equipment may result from faulty installation, improper
operation, inadequate or incorrect maintenance, and other forms of misuse
or abuse.
CAUTION: Ignoring information about potential hazards can lead to
serious harm to personnel and/or damage to equipment, and may
result in the nullification of the manufacturer’s equipment warranty.