Atmospheric Pre-aligner Manual
4000-0015 Rev 1
16
In the instructions for connecting the pre-aligner to the controller and
vacuum source, a side-connected pre-aligner is used as an example. Your
configuration might be side-connected or bottom-connected, as shown
here.
Be sure the controller is not connected to power. You will not connect the
power until all pre-aligner connections are made.
1. Connect three pre-aligner cables to the controller:
Motor power cable with eight-pin connector
Motor signal cable with 50-pin connector
Pre-aligner signal cable with CCD data connector.
2. Tighten the cable-locking screws to prevent accidental disconnection.
3. Attach the pre-aligner cables to the pre-aligner, as shown on this side-
connected pre-aligner:
Power cable
Data cable
Motor signal cable
signal power powersignal data
data
signal
signal
datapower
power
vacuum
vacuum
vacuum
data
Side connections for the 200 series
Side connections for the 300 series
Bottom connections for the 200 series Bottom connections for the 300 series