D950/Vista7 Digital Mixing System
Date printed: 27.08.03 SW V3.3 AutoTouch+ 5-113
5.14.4 AutoTouch+ Panel Presets
AutoTouch+ Panel settings may be stored and recalled as needed (D950
only). All switch states may be stored in any of four AutoTouch+ Panel
“Presets.” This is helpful when the same settings are used frequently. Pre-
sets may also be programmed to emulate V2.5 Automation Panel settings.
Storing AutoTouch+ Panel Preset: AutoTouch+ Panel Presets may be stored as follows:
1. Set all AutoTouch+ Panel controls to the desired state.
2. Hold the STORE key and press the desired Preset key (PRE A, PRE B,
PRE C, and PRE D).
Recalling AutoTouch+ Panel Preset: AutoTouch+ Panel Presets may be recalled as follows:
1. Press the Preset key (key (PRE A, PRE B, PRE C, and PRE D) for the
Preset to be recalled.
Long Term Storage: The contents of all AutoTouch+ Panel Presets, along with the current set-
tings, may be stored as part of a User File. Refer to chapter 5.17.
5.14.5 Function Keys
Function keys A1 and A2 (Vista) or F1...F3 (D950) are not implemented
(for future use).
5.14.6 Static Data (D950 only)
The STATIC key on the D950 AutoTouch+ Panel has two functions:
• When lit, the STATIC key indicates that Static Data Buffer is active and
there is a difference between the current Static values and those stored
within the current Mix Pass (Active Pass).
• Pressing the STATIC key clears the current Static values and those
stored within the current Mix Pass (Active Pass). This function cannot
be undone.
Notes: Static data may also be cleared by clicking the Clear Static button in the
AutoTouch+ window.
In the “Automation Options – Misc” menu (also refer to chapter 5.21.8),
static objects can be protected under certain circumstances.