Page #537 background imageLoading...
Page #537 background image
D950 Digital Mixing System
Date printed: 05.12.03 SW V3.3 System Administration 6-7
6.2 *.ini Files
The D950 process is inquiring the D950system.ini file during startup in order
to decide which controller threads should be started in the D950system.exe
process.
[d950systeminfo]
IsUS=No
NetIsUsed=No
HTTPIsUsed=No
IsAutoActive=Yes
IsBridgeActive=Yes
IsTestSystemActive=No
IsDeskActive=Yes
IsD19Active=Yes
IsGcActive=Yes
IsVistaActive=No
IsRegistryActive=Yes
IsMonActive=Yes
LastKnownIniFile=C:\D950SYSTEMDB\lastknownsession.INI
TccApplicationProgram=C:\D950SYSTEM\tcc02898.pgm
DefaultSystemdbDir=C:\D950SYSTEMDB
DefaultProductionDir=C:\D950PROJECTS
DefaultHTTPDir=C:\D950HTTP
MonitoringIniFile=
SysAdminPassword=
VmcTextOutput=No
VmcTextOutputFile=C:\D950SYSTEMDB\vmc.map
LogicalNetDriveName=
NetDriveName=
LogFile=C:\D950SYSTEM\D950system.log
// System stores all important information with this interval. Time in seconds, 1-86400. OFF=0
AutoSaveTime=0
[options]
TC2=Yes
TC3=No
MeterOverNet=No
DynamicAutomation=Yes
// If customer works with big mixes ( >15 MB), this option must be set to reserve memory. If no entry present,
// the value defaults to 10 MB. If value <5MB is entered, it defaults to 10MB.
MixSize=10
// "Yes" if the automatic drop-in should be done directly from D950 software by looking at the
// TC. "No" if the recorder should get IN and OUT points and should do the edits itself.
DO_AUTO_REC_EE=Yes
// If user wants to have REHEARSE and AUTO REC work multiple times when looping, this
// option must be set to "Yes" (Postroll time should be set to 0). Otherwise the machine may go into PLAY after
// having done the edit once.
IssueEditCommandAtLoopEnd=No
// 9Pin Record mode: "CrashRec" or "NoRec" (recording blocked) or "EditOnOff".
9PinRec=EditOnOff
// wrap around 24hours. "No" means that locating will stop at 0 or 23:59:59.ff. "Yes" means
// that yero crossing is allowed when working with offset set in the TC reader.
TC_ZERO_CROSS=No
// enter number of Pec/Dir panels. "0" means no Pec/Dir panel. Max no is "2". In software
// versions newer than 3.0 Pec/Direct panels are not supported anymore.
Pec/Direct=0