D950 Digital Mixing System
Date printed: 05.12.03 SW V3.3 System Administration 6-9
• IsBridgeActive=Yes/No
The bridge threads should be started. It is important that the memnet card
and driver are installed properly, else the threads would not start.
• IsTestSystemActive=Yes/No
The test system should be started instead of the bridge thread. The test
system is using the COM2 serial interface instead of the memnet card to
communicate with the DSP card. Please be careful that not both system are
active.
• IsDeskActive=Yes/No
The desk threads should be started. It is important that the hardware and
drivers for the desk communication are installed properly, otherwise the
threads would not start.
• IsGcActive=Yes/No
The GC part of the D950system.exe is activated as well as the GC control
thread.
• IsRegistryActive=Yes/No
The registry thread should be started.
• IsMonActive=Yes/No
The monitor threads should be started. It is important that the serial inter-
face card is installed properly, otherwise the threads would not start.
• LastKnownIniFile=C:\D950SYSTEMDB\lastknownsession.ini
The keyword points to the .ini file which indicates the last used session
and last used production/title.
• TccApplicationProgram=C:\D950SYSTEM\tcc00497.pgm
This file is downloaded to the time code card by one of the automation
threads.
• DefaultSystemdbDir=C:\D950SYSTEMDB
This path is the starting directory level for the file box in changing a ses-
sion.
• DefaultProductionDir=C:\D950PROJECTS
This path is the starting level for the file box in opening/saving a title.
• DefaultHTTPDir=C:\D950HTTP
• SysAdminPassword=
The password is needed to gain access to the system administration menu
on the GC.
6.3 lastknownsession.ini
The lastknownsession.ini file is used to save the last used or known session
configuration path/name and production/title. Its structure is identical with
the ones of the standard profiles. Name and location of the file are part of
the standard profile. There is one lastknownsession.ini file present in the
system. It is updated from the d950system application.
If the standard profile is not available, the system searches for:
\D950system\D950SYSTEMDB\LASTKNOWNSESSION.INI.
Keywords:
[lastknowndata]
CurrentSession=<session directory name including path>
CurrentMonitoringIniFile=<monitoring config. file name incl. path>
CurrentTitle=<title directory name including path>
If no title is open, the
CurrentTitle
string is empty.
If no configuration is available the
CurrentSession
string is empty.