D950/Vista7 Digital Mixing System
5-194 AutoTouch+ SW V3.3 Date printed: 27.08.03
5.21.8 Miscellaneous
This option page contains options not addressed elsewhere.
Protect Static: <When Stopped>: Changes to Static objects will be ignored unless the
system is “Mixing” (timecode running or stop frame mode).
<For Protected Controls>: When a control is protected (out of scope)
changes to the control will not be stored as Static values. They can be
auditioned and will return to their stored value when a new Mix Pass is
started.
<For Non-Automated Controls>: Changes to Non-Automated objects (like
Pan Format) will not be stored as Static values. They can be auditioned
and will return to their stored value when a new Mix Pass is started.
<From Kill Pass>: Stored Static values are not affected by Kill Pass op-
erations.
Modified Un-touch Inverts: <Touch Record>: The AUTO MODE key acts as a modifier key for certain
functions. For example, if the modifier key is held when an enabled con-
trol is touched, the control will or won’t go into record based on the in-
verse of the setting of the Touch Record function (of the AutoTouch+
Panel). Normally, when this radio button is selected, when un-touching a
control, if the modifier key is held, the Touch Record functionality is again
reversed.
<Touch Hold>: By selecting this option, when un-touching a control, the
effect of Touch Hold is reversed rather than that of Touch Record.