EasyManuals Logo

Studer D950 User Manual

Studer D950
648 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #561 background imageLoading...
Page #561 background image
D950 Digital Mixing System
Date printed: 05.12.03 SW V3.3 System Administration 6-31
; [MPU_0] first Multiformat Panning Unit with logical Node No. (starting with 0)
; MasterAddr= connected to HDLC Master x (1..NumberOfHDLCMaster)
; HDLC master address 0 = IP module A
; HDLC master address 1 = IP module B
; HDLC master address 2 = IP module C
; HDLC master address 3 = IP module D
; HDLCAddr= corresponds to Mpu HDLC address (starting with 244)
; ApplicationFilename= location and name of Application to download (j9504902.pgm)
[MPU_0]
MasterAddr=1
HDLCAddr=244
ApplicationFilename=C:\D950SYSTEM\j9504902.pgm
; [CAS_0] first Central Assign Section Unit with logical Node No. (starting with 0)
; MasterAddr= connected to HDLC Master x (1..NumberOfHDLCMaster)
; HDLC master address 0 = IP module A
; HDLC master address 1 = IP module B
; HDLC master address 2 = IP module C
; HDLC master address 3 = IP module D
; HDLCAddr= corresponds to Cas HDLC address
; starting with 128 and multiple of 16 (eg. 128 or 144 etc.)
; DeskLocation= corresponds to the physical location on the Desk (Left/Right dft:Left)
; Note: If more than 1 CAS declared with no desk location description,
; the multiple CAS work in parallel over the entire desk
; ApplicationFilename= location and name of Firmware Application to download for update
; Note: cas010320.s19 is mandatory if you update to D950 Rel V2.5
; The Application file is not mandatory for normal operation,
; it is only used for firmware updates on the CAS module.
[CAS_0]
MasterAddr=0
HDLCAddr=128
DeskLocation=Left
ApplicationFilename=C:\D950SYSTEM\cas010320.s19
; [BLOCKED_KEYS] Blocked (inaktive) key definition section
; (for key numbering see KeyNumber.xls)
; NumberOfBlocked4ChStripKeys=2 number of blocked keys on each strip
; on every 4ChStripNode
; Blocked4ChStripKey0=3 inactive key number 0..51 ( 3 == Channel ON key)
; Blocked4ChStripKey1=10 inactive key number 0..51 (10 == Clipbpard CLR key)
;
; NumberOfBlockedCauKeys= number of blocked keys on Central Assign Unit (CAU)
; BlockedCauKey0= inactive key number 0..79
; ...............
; NumberOfBlockedAcuKeys= number of blocked keys in old Automation Control Unit (ACU) V2.5
; BlockedAcuKey0= inactive key number 0..23
; ...............
; NumberOfBlockedAmpKeys= number of blocked keys in new Automation Master Panel (AMP) V3.0
; BlockedAmpKey0= inactive key number 0..51
; ...............
; NumberOfBlockedCsuKeys= number of blocked keys in Central Select Unit (MMS/BSU/CFU)
; BlockedCsuKey0= inactive key number 0..19 -> MMS;
; 20..39 -> BSU;
; 40..59 -> CFU;
; Note: same keys on 2nd MMS/BSU/CFU are inactive,
; if 2nd MMS/BSU/CFU is installed
; ...............
; NumberOfBlockedMpuKeys= number of blocked keys on each half
; on every MpuNode (Joystick)
; BlockedMpuKey0= inactive key number 0..12
; ...............
; NumberOfBlockedCasKeys= number of blocked keys on every CasNode
; (Central Assign Section)
; BlockedCasKey0= inactive key number 0..182

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Studer D950 and is the answer not in the manual?

Studer D950 Specifications

General IconGeneral
BrandStuder
ModelD950
CategoryMusic Mixer
LanguageEnglish

Related product manuals