D950 Digital Mixing System
Date printed: 05.12.03 SW V3.3 System Administration 6-31
; [MPU_0] first Multiformat Panning Unit with logical Node No. (starting with 0)
; MasterAddr= connected to HDLC Master x (1..NumberOfHDLCMaster)
; HDLC master address 0 = IP module A
; HDLC master address 1 = IP module B
; HDLC master address 2 = IP module C
; HDLC master address 3 = IP module D
; HDLCAddr= corresponds to Mpu HDLC address (starting with 244)
; ApplicationFilename= location and name of Application to download (j9504902.pgm)
[MPU_0]
MasterAddr=1
HDLCAddr=244
ApplicationFilename=C:\D950SYSTEM\j9504902.pgm
; [CAS_0] first Central Assign Section Unit with logical Node No. (starting with 0)
; MasterAddr= connected to HDLC Master x (1..NumberOfHDLCMaster)
; HDLC master address 0 = IP module A
; HDLC master address 1 = IP module B
; HDLC master address 2 = IP module C
; HDLC master address 3 = IP module D
; HDLCAddr= corresponds to Cas HDLC address
; starting with 128 and multiple of 16 (eg. 128 or 144 etc.)
; DeskLocation= corresponds to the physical location on the Desk (Left/Right dft:Left)
; Note: If more than 1 CAS declared with no desk location description,
; the multiple CAS work in parallel over the entire desk
; ApplicationFilename= location and name of Firmware Application to download for update
; Note: cas010320.s19 is mandatory if you update to D950 Rel V2.5
; The Application file is not mandatory for normal operation,
; it is only used for firmware updates on the CAS module.
[CAS_0]
MasterAddr=0
HDLCAddr=128
DeskLocation=Left
ApplicationFilename=C:\D950SYSTEM\cas010320.s19
; [BLOCKED_KEYS] Blocked (inaktive) key definition section
; (for key numbering see KeyNumber.xls)
; NumberOfBlocked4ChStripKeys=2 number of blocked keys on each strip
; on every 4ChStripNode
; Blocked4ChStripKey0=3 inactive key number 0..51 ( 3 == Channel ON key)
; Blocked4ChStripKey1=10 inactive key number 0..51 (10 == Clipbpard CLR key)
;
; NumberOfBlockedCauKeys= number of blocked keys on Central Assign Unit (CAU)
; BlockedCauKey0= inactive key number 0..79
; ...............
; NumberOfBlockedAcuKeys= number of blocked keys in old Automation Control Unit (ACU) V2.5
; BlockedAcuKey0= inactive key number 0..23
; ...............
; NumberOfBlockedAmpKeys= number of blocked keys in new Automation Master Panel (AMP) V3.0
; BlockedAmpKey0= inactive key number 0..51
; ...............
; NumberOfBlockedCsuKeys= number of blocked keys in Central Select Unit (MMS/BSU/CFU)
; BlockedCsuKey0= inactive key number 0..19 -> MMS;
; 20..39 -> BSU;
; 40..59 -> CFU;
; Note: same keys on 2nd MMS/BSU/CFU are inactive,
; if 2nd MMS/BSU/CFU is installed
; ...............
; NumberOfBlockedMpuKeys= number of blocked keys on each half
; on every MpuNode (Joystick)
; BlockedMpuKey0= inactive key number 0..12
; ...............
; NumberOfBlockedCasKeys= number of blocked keys on every CasNode
; (Central Assign Section)
; BlockedCasKey0= inactive key number 0..182