Chapter 1 – Before You Begin
Firmware Version 3/4.31.37
3. Press Next until Meters is highlighted. Press Enter. The Meter Setup screen displays:
1.4 INFORMATION ALERTS
The Guide uses the following graphical conventions to alert the reader to different kinds of information:
Notes provide additional, supplementary, or “nice-to-know” information not actually necessary to the
current task or topic.
Cautions alert you to the possibility of unexpected results when performing an action. They are
also used to inform you of important things to keep in mind.
Warnings inform you of the possibility that damage might occur as a result of performing a certain
action or not performing a certain action. Pay close attention when you see the warning symbol!
PRE #1 MTR #1 SETUP
Flow Control Module#: 0
Side-Stream on Mtr#: 0
Side-Strm on Any Mtr: DISABLD
Meter Type: VOL PUL
Max Quad Errors: 10
Reset Quad Errors: 10000
Low Flow Alarm Rate: 10
Low Flow Alarm Time: 10.000
Excess Flw Alrm Rate: 800
Minimum Flow Rate: 50
Maximum Flow Rate: 650
Low Flow DB Rate: 40
High Flow DB Rate: 40
1st Stage DB Rate: 40
Next Prev Exit Enter
EQUIPMENT SETUP MENU
Bay
Preset
Meters
Components
Additives
Samplers
Next Prev Exit Enter