Firmware Version 3/4.31.37
Regular product (Component Level) values are reported as:
Gr=Grem-Ge (value not to be used for trade)
Tr=((Trem * Grem) – (Te * Ge)) / Gr (value not to be used for trade)
Dr=Dr’ OR
Dr= ((Drem * Grem) – (De * Ge)) / Gr (value not to be used for trade)
Nr=Nrem-Ne (value not to be used for trade)
Mr=Mrem-Me (value not to be used for trade)
Where: Gr=Gross volume loaded for the Regular component
Grem-Ge=Gross volume loaded difference between Blend and Ethanol
Tr=Temperature for the Regular component
((Trem * Grem) – (Te * Ge)) / Gr=Back calculated average temperature for the Regular
component
Dr=Density for the Regular component
Dr’=Density specified for the Regular component
((Drem * Grem) – (De * Ge)) / Gr=Back calculated average density for the Regular component
(see Preset Level Parameter Compute Blend Density)
Nr=Net volume loaded for the Regular component
Nrem-Ne=Net volume difference between the Blend Net Volume and Ethanol Net Volume
Mr=Mass loaded for the Regular component
Mrem-Me=Mass difference between the Blend Mass and Ethanol Mass
Premium product (Component Level) values are reported as:
Gp=Gpm
Tp=Tpm
Dp=Dp’ OR Dpm
Np=Npm
Mp=Mpm
Where: Gp=Gross volume loaded for the Premium component
Tp=Temperature for the Premium component
Dp=Density for the Premium component
Dp’=Density specified for the Premium component
Np=Net volume loaded for the Premium component
Mp=Mass loaded for the Premium component
Pressure and Gravity are handled in the same way as Temperature and Density.
9.13 TEMPERATURE CALIBRATION FOR METERS
Use the Temperature screen to calibrate temperature for a meter.
1. From the Views amd Inquiries Menu, choose Temperature. After selecting the preset and meter, the
Temperature screen displays.