Chapter 10– Views and Inquiries
332
Firmware Version 3/4.31.37
Unauthorized Gross
Total unauthorized gross volume through the additive meter.
Meter Creep Gross
Gross amount of volume designated as meter creep. Meter creep volumes
are small amounts of volume that have been indicated by the meter when
flow is supposed to be idle. Meter creep can be caused by a small leak,
excessive line shock or electro-magnetic interference.
Notes:
- Numbers are displayed in 1/1000
th
of unit of measure. A decimal point is implied three positions to the
right of the least significant number.
- The numbers on the left indicate volumes in non-resettable totalizers.
- The numbers on the right indicate volumes in resettable totalizers.
Use the CLR key to zero out the resettable totalizers.
10.3.5 VIEWING SAMPLER TOTALIZERS
From the View Totalizers Menu, select Samplers. After selecting the preset and sampler, the Sampler Totalizers
screen will be displayed:
Parameter Descriptions:
Total Gross
Total gross volume through the additive meter.
Authorized Gross
Total authorized gross volume through the additive meter.
Notes:
- Numbers are displayed in 1/1000
th
of unit of measure. A decimal point is implied three positions to the
right of the least significant number.
- The numbers on the left indicate volumes in non-resettable totalizers.
- The numbers on the right indicate volumes in resettable totalizers.
PRE #1 SAMP #1 (Samp 001 ) TOTALIZERS
Total Gross:000000000 (000000000)
Authorized Gross:000000000 (000000000)
CLeaR Next Prev Exit

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Toptech Systems MultiLoad II and is the answer not in the manual?

Toptech Systems MultiLoad II Specifications

General IconGeneral
BrandToptech Systems
ModelMultiLoad II
CategoryControl Unit
LanguageEnglish

Related product manuals