Firmware Version 3/4.31.37
Saleable product (Preset Level) values reported as:
Gb=Gm
Tb=Tm
Db=Dm
Nb=Nm
Mb=Mm
Where: Gb=Gross volume loaded for the blend
Tb=Temperature for the blend
Db=Density for the blend
Nb=Net volume loaded for the blend
Mb=Mass loaded for the blend
Pressure and Gravity are handled in the same way as Temperature and Density.
9.7 MULTILOAD SEQUENTIAL BLENDING CALCULATIONS
Regular meter (Meter Level) values are reported as:
Grm=M1
Trm=T1
Drm=D1 OR Dr
Nrm=Grm*VCFr(Trm,Drm)
Mrm=Nrm * Dr OR Mrm=Grm * Dm
Where: Grm=Gross volume loaded for the Regular Meter
M1=Gross volume reported by meter M1 while flowing Regular
Trm=Temperature for the Regular Meter
T1= Volume weighted average temperature reported by probe T1 while flowing Regular
Drm=Density for the Regular Meter
D1=Volume weighted average Density measured while flowing Regular
OR specified for meter M1
Dr=Density specified for the Regular component
Nrm=Net volume loaded for the Regular Meter
VCFr=API Correction Table for Regular
Mrm=Mass loaded for the Regular Meter