Chapter 9 Weights & Measures
301
Firmware Version 3/4.31.37
Saleable product (Preset Level) values reported as:
Gb=Gm
Tb=Tm
Db=Dm
Nb=Nm
Mb=Mm
Where: Gb=Gross volume loaded for the blend
Tb=Temperature for the blend
Db=Density for the blend
Nb=Net volume loaded for the blend
Mb=Mass loaded for the blend
Pressure and Gravity are handled in the same way as Temperature and Density.
9.7 MULTILOAD SEQUENTIAL BLENDING CALCULATIONS
P
P
Premium
Regular
BV
T1
CV
M1
BV
Comp #1
Comp #2
Regular meter (Meter Level) values are reported as:
Grm=M1
Trm=T1
Drm=D1 OR Dr
Nrm=Grm*VCFr(Trm,Drm)
Mrm=Nrm * Dr OR Mrm=Grm * Dm
Where: Grm=Gross volume loaded for the Regular Meter
M1=Gross volume reported by meter M1 while flowing Regular
Trm=Temperature for the Regular Meter
T1= Volume weighted average temperature reported by probe T1 while flowing Regular
Drm=Density for the Regular Meter
D1=Volume weighted average Density measured while flowing Regular
OR specified for meter M1
Dr=Density specified for the Regular component
Nrm=Net volume loaded for the Regular Meter
VCFr=API Correction Table for Regular
Mrm=Mass loaded for the Regular Meter