Chapter 4 – General Configuration
Firmware Version 3/4.31.37
Prompting Mode which will prompt the driver to enter in observed values at the end of the load.
NONE: No prompting will be done.
BSW: Prompt for an Observed BSW value.
DENSITY: Prompt for an Observed Density value.
BSWDENS: Prompt for an Observed BSW and Observed Density value.
GROSS: Prompt for an Observed Gross value.
B G: Prompt for BSW & Gross only
D G: Prompt for Density and Gross only.
BDG: Prompt for BSW, Density, and Gross only.
TEMP: Prompt for Observed Temperature value.
B T: Prompt for BSW and Temp only.
D T: Prompt for Density and Temp only.
BD T: Prompt for BSW, Density and Temp only.
GT: Prompt for Gross and Temp only.
B GT: Prompt for BSW, Gross and Temp only.
DGT: Prompt for Density, Gross and Temp only.
BDGT: Prompt for all.
This parameter selects the unit of measurement that will be used for the sampling of products.
Options available are none, cc, and oz.
This parameter dictates the placement of SCS based “observed value” prompts being before
or after the transactions.
This parameter is at the moment only used in UAP mode. It defines the number of lines on
each printed ticket.
Allows connection of an external switch to gain write access to W&M parameters. Set this
parameter to the FCM and Port for the input where the switch is attached. The input value at
this location will be ORed with the MultiLoad II W&M switch status. RCU Diagnostic will show
that status of this switch.
Allows connection of an external switch to gain write access to program mode. Set this
parameter to the FCM and Port for the input where the switch is attached. The input value at
this location will be ORed with the MultiLoad II program mode switch status. RCU diagnostics
will show the status of this switch
At startup of the MultiLoad II the keypad is locked or not locked. The only screen where the
keypad is still working is the IDLE Screen. So the Configuration Menu is always accessible.
Brightness of the Display
Enter MultiLoad II RCU address. Valid entries are 001-099. Toptech strongly recommends
use of address 001 for all MultiLoad IIs.
4.6 SECURITY SETUP
The Multiload can isolate what a user, based on their security level, can change regarding parameters as dictated
by default supplied security levels or eventually ADMIN user modified levels. To repeat, each user is supplied a
set level upon creation of that user. That level, at the point of attempting a parameter change, is judged against
the parameters security level and if the user level is equal to or higher than the parameter security level, the
change will be allowed. Otherwise the user will be alerted by a temporary screen message of the level required to
make the change. The levels are shown below: