Chapter 9 – Weights & Measures
288
Firmware Version 3/4.31.37
Table
Description
TABLE HYDRO
BRAZIL
This table provides CTL factors for correcting volumes of hydrocarbons at observed
temperatures to the volume at 20ï‚° C . Use this table if the following conditions exist:
ï‚· The liquid is alcohol
ï‚· Current Temperature and Density at 20ï‚° C is available.
Test temperatures can be entered on this screen that will calculate a CTL based on the test
temperature and density. The test temperature and Calculated CTL are for informational
purposes and will not be used in calculations during operations.
Product
Min Temp
Max Temp
Min Dens20
Max Dens20
LPG
-50
75
498
700
Gasoline
-25
75
700
800
Diesel, Lubes
-25
125
800
900
Crude Oil,
heavy oils, …
0
200
900
1200
Corrected density at observed degree will be calculated and stored.
ASTM 1250-
2004 Table 5A
This table provides the API gravity at 60ï‚° F of crude oil at observed temperature and API
gravity. Use this tables if the following conditions exist:
The liquid is crude oil
Current temperature and API gravity is known
API gravity at 60ï‚° F is unknown
ASTM 1250-
2004 Table 5B
This table provides the API gravity at 60ï‚° F of refined products at observed temperature and
API gravity. Use this table if the following conditions exist:
ï‚· The liquid is a refined product
ï‚· Current temperature and API gravity is known
API gravity at 60ï‚° F is unknown
ASTM1250-
2004 Table 5D
This table provides the API gravity at 60ï‚° F of lubrication oil at observed temperature and
API gravity. Use this table if the following conditions exist:
The liquid is lubrication oil
Current temperature and API gravity is known
API gravity at 60ï‚° F is unknown
ASTM1250-
2004 Table 5X
This table provides the API gravity of a petroleum product at observed temperatures and
API gravity. This table allows specifying the commodity being measured, the reference
temperature, and units of measure for density, pressure, and temperature.
ASTM1250-
2004 Table 6A
This table provides CTL factors for correcting volumes of crude oil at observed
temperatures to the volume at 60ï‚° F, using the method outlined in Chapter 11.1.6.1 of the
2004 standard. Use this table if the following conditions exist:
ï‚· The liquid is crude oil
ï‚· API Gravity @ 60 ï‚°F is known
Reference Temperature is 60ï‚° F

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Toptech Systems MultiLoad II and is the answer not in the manual?

Toptech Systems MultiLoad II Specifications

General IconGeneral
BrandToptech Systems
ModelMultiLoad II
CategoryControl Unit
LanguageEnglish

Related product manuals