Chapter 13 – Custom Logic
402
Firmware Version 3/4.31.37
Parameter
Description
Additive State
Indicates the current state of the specified Additive.
Each state will be represented as a numerical value
(see below).
State
Numeric Value
Inactive
0
Ready
1
Injecting
2
Last Injection
3
Shutoff
4
Missed Injections
Indicates the current number of missed injections, of
the specified additive, for the current batch.
Creep Gross
The current gross volume that has flowed through the
specified additive’s meter outside of the injection time
configured. Value is in thousandths with an implied
decimal.
Unauthorized Gross
The current gross volume delivered, of the specified
additive, which was not authorized to be loaded. Value
is in thousandths with an implied decimal.
Sampler Real Time (RT)
Parameter
Description
Clearing Errors
Indicates that a sampler-level alarm is clearing for a
particular sampler.
Clear Batch
Indicates that sampler totals of a particular injector are
being archived.
Alarm Out
Indicates that a sampler-level alarm, such as Injector
Fault, is active for a particular sampler.
Authorized
Indicates when a driver is authorized to use a particular
sampler.
Permissive
Indicates that a sampler-level permissive has been
received.
Permissive Out
Indicates that all sampler-level permissives have been
satisfied.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Toptech Systems MultiLoad II and is the answer not in the manual?

Toptech Systems MultiLoad II Specifications

General IconGeneral
BrandToptech Systems
ModelMultiLoad II
CategoryControl Unit
LanguageEnglish

Related product manuals