Chapter 16 Firmware Revision History
509
Firmware Version 3/4.31.37
Fix: Audit Logging of the Group Security Level for Trace parameters. The security level
for all Trace parameters fall under the Trace Group Security Level. If the user attempts to
change the security level for an individual Trace parameter, it will change all other Trace
parameters. The Audit Logging of this was broken, and would display "Security Lvl:unused ##
changed to ##".
12/20/2015 TF
Fix: The save transactions to SD Card functionality could potentially cause a Blue
Screen. Power cycling the unit would not solve the problem. The user would need to remove
the SD Card and then power cycle unit to get rid of the Blue Screen.
12/28/2015 WJP
Updated factory setting of MAC addresses to support new MAC address range.
1/13/2016 TF
Increased firmware version to x.31.28
Fix: If viewing the SCS Batch Reports in the Views & Inquiries menu, the weighted
averages were not being calculated at all and would display 0.
1/19/2016 TF
Increased the maximum amount of digits displayed on the Preset Status screen to display
up to 5 digits before the decimal place. This only applies when "Display Hundredths" is
enabled.
Fix: Bug found in SCS Build related to the SCS Batch Reports. If the user carded in
trying to end a sampler batch and there wasn't a PIN number associated with the card, the
custom prompts would still be displayed to the user.
2/8/2016 TF
Fix: Failed to update the logmsg_queued flag which TMS looks at to determine if it needs
to download new log messages. Log messages failed to make it up to TMS automatically after
v23. The workaround is to send the "R910" command manual, which tells TMS that there are
log messages queued to be sent.
2/9/2016 TF
Fix: Bug when saving an FCM address parameter to a configuration file. If the parameter
was configured to point to a Custom Logic line, the routine that converted the FCM Address
from internal representation to external representation didn't format the bits correctly.
Fix: Blue Screen that would occur if in UAP mode, SCS Prompts were enabled, and the SCS
prompts were displayed at the before of the load. If the user exited out of the SCS Prompts
without completing them, we would call ml_prompts_deinit() a second time which would
attempt to destroy the lua context that has already been destroyed.
Fix: Additive Transaction Detail screen displayed "Alarm:" instead of "Target:" and
"Delivered:"
2/10/2016 MSH
Refactor UAP trace levels to make default logging less verbose.
Changed UAP trace levels to use UNIX-style levels. Changed default trace level to
"ERROR".
2/11/2016 TF
Added functionality that will save/reload the configuration to/from flash when upgrading
firmware.
Fix: Preset Status screen display of delivered gross, net, and mass. The screen would not
use a comma when displaying hundredths when decimal_mark was configured for a comma.